MeristemLiving roof systemsTechnical portal

Meristem TERRACE

Occupied roof: lawn, shrubs, trees, paving, and the structure to hold them.

Optimised for Usable square footage on the roof plane
Depth
12–24" (300–600 mm)
Saturated load
120–190 lb/ft² saturated
Annual retention
78%
Max slope
to 1:12
Wind
Assembly ballasted; wind design by EOR
Fire
ASTM E108 Class A
Planting
Lawn, shrub and semi-mature tree pits to 8 m
Maintenance
Landscape contract, 8+ visits/year
Install rate
1,200 ft²/day, 4-person crew
Exploded assembly12–24" (300–600 mm) · 120–190 lb/ft² saturated
Lawn, planting + pavingMixed hard and soft landscape40 mmGrowing media, intensiveDeepened to 600 mm at tree pits260 mmFilter fabricNon-woven PP, 6 oz5 mmReservoir board0.9 gal/ft² + sub-surface irrigation grid40 mmProtection matRated for construction traffic10 mmRoot barrierFLL-tested, 0.5 mm HDPE, loose laid6 mmWaterproofing (by others)Assembly is membrane-agnostic10 mmSTRUCTURAL DECK (BY OTHERS)
Specified when
  • Podium decks + amenity terraces
  • Hospitality + multi-residential
  • Roofs sold as leasable space
Occupied amenity spaceBiodiversity + habitatStormwater performance
Previously sold as

If a drawing in your set names one of these, it is asking for Meristem TERRACE.

  • Verdura Eco-DeepVED

    Split from the intensive line; tree-pit detail is now a separate drawing.

  • ED-300ED-300

    Renamed only. 300 mm profile unchanged.

Technical documents

11 documents cover this system

Open the portal →
DOCX

CSI 3-part specification — Meristem TERRACE

Specification · v4.1

DWG

Typical assembly details — all systems

CAD + BIM · v9.0

DWG

Drain, penetration and expansion-joint details

CAD + BIM · v9.0

PDF

Load table — saturated and dead loads, all systems

Performance data · v3.1

PDF

Wind uplift test report — ANSI/SPRI RP-14

Performance data · v2.2

PDF

Fire classification certificate — ASTM E108

Performance data · v1.4

PDF

Installation manual — TERRACE

Installation · v6.2

PDF

Pre-installation checklist + membrane sign-off

Installation · v3.0

PDF

Maintenance schedule + plant establishment care

Maintenance · v5.1

PDF

Warranty registration form

Warranty + safety · v4.0

PDF

Safety data sheet — engineered growing media

Warranty + safety · v2.1

Built with Meristem TERRACE