Six vegetated assemblies, each specified against a number an engineer can hold us to: saturated load, retained rainfall, wind uplift, panel yield. Built in Ontario since 2006.
2.4M
ft² installed since 2006
6
systems, one document set
92%
peak annual retention
20 YR
system warranty, registered
New names. Same assemblies.
Every product was renamed in 2026 when we split the range by what it is engineered to do rather than how thick it is. Nothing was discontinued and no build-up changed without a revision note.
Holding a drawing that calls out V-Lite 100 or ED-300? Type the old name and we will tell you what it is now and what changed with it.
Look up an old nameSix systems, one document set
Compare all specificationsExtensive
26 lb/ft² saturated
The thinnest full assembly we build, for decks with nothing left to give.
- Depth
- 4"
- Slope
- 2:12
- Retention
- 55%
Extensive
32 lb/ft² saturated
Pre-grown modules that land planted and come up for deck access.
- Depth
- 4.5"
- Slope
- 3:12
- Retention
- 50%
Semi-intensive
44 lb/ft² saturated
A seeded native meadow, specified for habitat outcomes and audited for them.
- Depth
- 6"
- Slope
- 2:12
- Retention
- 65%
Performance
55 lb/ft² saturated
A detention assembly with plants on it. Sized to a hydrograph, not a depth.
- Depth
- 8"
- Slope
- 1:12
- Retention
- 92%
Intensive
120–190 lb/ft² saturated
Occupied roof: lawn, shrubs, trees, paving, and the structure to hold them.
- Depth
- 12–24"
- Slope
- 1:12
- Retention
- 78%
Performance
38 lb/ft² saturated
The array is ballasted by the roof it stands in, and runs cooler for it.
- Depth
- 5"
- Slope
- 2:12
- Retention
- 58%
We stopped selling depth and started selling outcomes.
Sized to a hydrograph
Stormwater systems are specified from the civil release rate. Depth is an output of the calculation, not a product choice.
Habitat that is audited
Meadow roofs ship with an ecoregion seed schedule and a two-year establishment audit, so the biodiversity claim survives handover.
Load on the drawing
Saturated load, wind uplift and fire class for every assembly live in one table the structural engineer can pull before design development.
Recent roofs
All projectsThe technical library sits behind one login.
Editable CSI specifications, CAD and Revit details, load tables, wind and fire reports, installation manuals and warranty forms. Access is granted by role, so a contractor sees the handling manual and a specifier sees the drawing set.
- SpecificationCSI 3-part, editable, per system
- CAD + BIMDWG detail set · Revit families
- Performance dataLoad, wind, fire, stormwater
- InstallationManuals, checklists, sign-off forms